CT600/602/610 and CT300/310 BKC-DIP Product Specific Appendices
Version 2.00.09
Updated 12/15/06
Page 38 of 48
Appendix M, Error Logs
(0,G,E,0;cs16) Example of Get Primary Preset Errors
(0,S,E,0=0;cs16) Example of Set Primary Preset Errors
Identifier Description Note
(in hex)
00 Primary Preset Error Log Note 1
01 Secondary Preset Error Log Note 1
02 Primary System Error Log Note 2
03 Secondary System Error Log Note 2
04 Primary Preserved Error Log Note 3
05 Secondary Preserved Error Log Note 3
06 Serial Number Error Log Note 4
07 Signature Error Log Note 5
08 Non Volatile Write Error Log Note 6
Appendix M, Error Logs Parameter Notes
General Note 1: If error is detected in the primary preset memory, the
error is logged as a primary error, then the settings are
recovered from the secondary (backup) settings. If the
secondary settings are corrupted, the error is logged as a
secondary error, and the settings are forced to their default
value.
General Note 2: Error Logs are not reset by factory reset. To clear
error logs, the value of 0 must explicitly be written to each
identifier via a BKC-DIP set (S), command.
Note 1: Indicates data corruption in Preset primary/secondary
settings.
Note 2: Indicates data corruption in System primary/secondary
settings.
Note 3: Indicates data corruption in Preserved primary/secondary
settings.
Note 4: Indicates data corruption of one of the redundant serial
number entries.
Note 5: Indicates data corruption of one of the redundant signature
entries.
Note 6: Indicates general low level write error to non-volatile memory
device.