CT600/602/610 and CT300/310 BKC-DIP Product Specific Appendices
(BKC-DIP) B&K Components Device Interface Protocol
Version 2.00.04
Updated 12/15/06
Page 48 of 48
Note 7: 0h = BKC-DIP V1.0 compliant, 1h = BKC-DIP V2.0 compliant with no attributes, 2h = BKC-DIP V2.0 compliant
with attributes.
Note 8: Bitmap indicating which Hardware Zones (Zones A, B, C, D, E or F) to allow RS-232 data to be output. If
the bit is set, the data will be output.
Zone A 01h
Zone B 02h
Zone C 04h
Zone D 08h
Zone E 10h
Zone F 20h
Thus an output mask of 2Bh would allow serial port data to be output on Zone A, Zone B, Zone D and Zone
F, but NOT on Zone C and Zone E.
NOTE: The serial port data is always transmitted out the “primary” serial port connection, i.e. the RJ45 connector. An output mask of 00h will mask all
data to the Hardware Zone outputs, but the data will still be transmitted to the primary serial port.
Appendix Q, Status Messages
(0,U,S,0="BKC-DIP ACTIVE";05FE) Example Status Message
Message Number Message Indication
0 (receiveID,U,S,0="BKC-DIP ACTIVE";cs16) BKC-DIP interface is active an the Device is ready to accept
BKC-DIP commands
4 (receiveID,U,S,4="za zb … zn";cs16) String containing current Logical Zones in
system, delimited by whitespace.
For example default CT610 and CT600 zones:
(0,U,S,4="0 B C D E F 10";)
5 (receiveID,U,S,5=”Pz=nn”; cs16) Logical Zone z Preset nn updated, where z can
range from 0h – 80h, and nn 0h – FEh
5 (receiveID,U,S,5="S";cs16) System parameters updated
Commenti su questo manuale